Masonry Protection Package Eliminates Construction Problems

Cavity wall openings must appropriately interface lintel /opening protection with vertical reveal-closing protection. 

The construction arrangement need not be problematic where the external skin style and the frame setback are non-standard. 

What is essential is that the relationship between both is correctly formed and provision is made for water evacuation. 

With the growing use of composite (faced brick effect) lintels and deeper masonry reveal arrangements, the benefit of ‘Opening Protection Packages’ is highlighted. 

Cavity Trays of Yeovil is now supplying Opening Protection Packages, offering preformed solutions that not only provide an assured detail

but also reduce wastage and eliminate construction fabrication error.

Type C Cavitrays are preformed protective trays for use with all styles of lintel support.  

As well as being ready-shaped they are supplied cut to length. 

Thus the usual necessity of having to cut damp course, arrange it and then support it within both skins (to provide shape) are eliminated.

Preformed also means there is no danger of sagging or distortion – common with soft roll dpc. 

Trays can be instantly incorporated and a consistent detail established every time. 

The ends of each tray project and oversail the tops of the vertical Cavicloser built in to close, insulate and act as a damp course between outer and inner skins. 

In the example photograph the oversail was extended to terminate in excess of 225mm beyond the masonry opening.

This overcame the problem of water evacuation not being possible through the faced composite lintel and permitted the use of discreet Caviweeps within the perp joints away from the masonry opening. 

Visually the use of preformed Cavitrays, Caviclosers and Caviweeps extends the design options available to the Architect and Contractor whilst promoting functionality without sacrificing aesthetics. 

Type C Cavitrays / profiles are available to suit standard and non-standard opening arrangements. 

Caviclosers are available to suit walls of all styles with cavity widths up to 200mm. 

Six styles of Caviweep/Cavivent are offered to harmonise with the masonry and /or mortar. 

Opening Protection Packages do exactly what they say. And the elimination of waste is accompanied with accurate costing and accurate scheduling. 

CAVITY TRAYS LTD

August 2010. 

END

News Headlines

April 2013
Cavity Trays Approval Advantage

 
November 2012
Flashing Functionality an Important Consideration in Severe Weather, advises Cavity Trays Ltd

 
House Builders on The Same Level

 
October 2012
When Laying A Slate Roof to NHBC Standards Consider A New Version of A Traditional Ventilator

 
August 2012
Go Round the Masonry Bend with Assured Detail

 
July 2012
Latest Book of Wise Decisions 2012 Edition now available

 
April 2012
Cavity Trays More Customer Benefits

 
December 2011
NHBC Technical Extra – Level Thresholds and DPC Integration

 
November 2011
Cavity Trays wins at the Housebuilder 2011 Awards

 
October 2011
Water Penetration at 6 o’clock

 
New Article - Water Evacuation without Visual Impairment

 
Cavity Trays Production Uses Photovoltaic Panel Power

 
September 2011
Follow us on Facebook and Twitter

 
UK Builders Alerted by World Health Organization

 
August 2011
Synthetic flashing with no theft appeal

 
July 2011
Using a vapour permeable underlay does not negate the need for traditional ventilation

 
Gable Abutments - Consider the Relationship Between Inner and Outer Skins

 
Lintel + Roller Shutter + Security - Cavilintel offers more

 
June 2011
Cavity Wall Openings with a Difference

 
Why Protecting Partial Fill Insulation in a Gable is Essential

 
May 2011
New Product Guide 22 Available Now!

 
Acoustic + Thermal + DPC Undersill Tray

 
Latest Book of Wise Decisions now available

 
April 2011
New Cavity Closer - Improved Thermal Efficiency for Cavity Widths up to 330mm

 
January 2011
Rendered Walls - Water Exit Routes are Essential

 
Cavity Barrier Problem

 
Double Arrestment Benefit of Multi-Opening Cavitray

 
December 2010
Level Threshold Deterioration Avoidance

 
Masonry Skin Levels and DPC’s

 
November 2010
Cavity Wall Water Evacuation is Essential

 
Multicourse Cavitrays - Protection Compatibility

 
October 2010
Why Water Penetration Around Some Arches is 80% Higher

 
An Easier and More Effective Traditional Build Detail

 
Cold Bridging and Dampness around Masonry Cills

 
Static Cavity Walls Can Move - Beware DPC Slip Planes

 
Continuity with Corbel Cavitray

 
September 2010
Expanding Bespoke Service in Cavitrays and Caviclosers

 
Ventilator Offers More Choice - and Cost Savings

 
Rain Amplification with Curved Cavity Walls

 
Circular Cavitrays up to 3 Metres

 
August 2010
Masonry Protection Package Eliminates Construction Problems

 
Cavity Trays increases fire integrity of hatches

 
June 2010
Good News! The New Part L and NHBC Conservatory Construction

 
May 2010
Construction Compliant Cavitrays

 
April 2010
Cavity Trays approved by GreenSpec

 
March 2010
SIPS panel profiled DPC's - New Product

 
February 2010
New Circular Louvered Vent for existing walls

 
Cavity Trays joins The Green Organisation

 
January 2010
New Product - Level Threshold Tray

 
May 2009
Party Walls - Compliancy and Functionality Solution